Great service, professional technician!
Kelley - Covington, GA 30014
Quick Service
Kelley - Covington, GA 30014
Luis M.
Luis M.
Luis M.
Luis M.
Luis M.
Luis M.
Kenneth Y.
Service work to be quoted: (26)-10lb abc due for 6 year maintenance (2)-10lb abc due for hydro test (1)-10lb abc recharge (1)-10lb abc new (4)-5lb abc due for 6 year maintenance (3)-5lb abc due for hydro test (2)-2.5lb abc new (3)-10lb co2 due for hydro test (1)-5lb fe36 due for 6 year maintenance
Kenneth Y.
Annual Security Fence inspection. Includes visual only inspection for coverage and condition, including gap from ground level. This is for main location at 14187 Nisshinbo Drive only. Annual visual inspection of perimeter lighting of building and street lighting in parking lot. Includes verification of light turning on and is for main location at 14187 Nisshinbo Drive only. Annual hand-held radio coverage inspection. Includes verification of radio coverage between units from one end of the facility to the other. This is for main location at 14187 Nisshinbo Drive only. Annual Portable Extinguisher Inspection (145) per NFPA 10. BRC# 707019 Annual Emergency/Exit Light Inspection (167) per NFPA 101. Annual Eye Wash Station Inspection (20) Annual AED Inspection (2) Annual Fire Door Inspection (8) per NFPA 80/1010 - includes replacement of fusible links Monthly Safety Inspection including Portable Fire Extinguishers, Emergency/Exit Lights, Eye Wash Stations, and AEDs. 2018 PO# 57565 BRC
Troy L.
Alarm service Call AFP-200 is not working. Replaced batteries yesterday batteries quit working today. Advised that the circuit breaker makes a weird noise.
Troy L.
Access Control Installation
Troy L.
Troy L.
Alarm Systems Service Call
Luis M.
Luis M.
Bert P.
Alarm Systems and Distributed Communications Inspection Annual Fire Alarm System Inspection (1) in NAMI1 per NFPA 72. Annual Fire Alarm System Inspection (1) in NAMI2 per NFPA 72. Annual EVAC/PA Inspection (1) per NFPA 25 Inoperable Deficiency: NAMI 2 Power Supply Above FACP had AC and Battery troubles prior Inspection. Need to investigate and repair. FACP and FCPS Batteries have no Dates and need to be replaced (12v/7amp).
Bert P.
Sprinkler, Fire Hydrant, and Fire Pump Inspection Annual Wet Sprinkler System Inspection (9) per NFPA 25 (9) at 14187 Nisshinbo Drive Annual Fire Hydrant Inspection (3) per NFPA 25 Annual Fire Pump Inspection (1) per NFPA 25 Quarterly Sprinkler Inspection (9) per NFPA 25 (9) at 14187 Nisshinbo Drive
Kenneth Y.
Annual Portable Extinguisher Inspection (145) per NFPA 10. Annual Emergency/Exit Light Inspection (167) per NFPA 101. Annual Eye Wash Station Inspection (20) Annual AED Inspection (2) Annual Fire Door Inspection (8) per NFPA 80/1010 - includes replacement of fusible links Monthly Safety Inspection including Portable Fire Extinguishers, Emergency/Exit Lights, Eye Wash Stations, and AEDs. 2018 PO# 57565 Deliver (1) 30 lb. Class D Copper Extinguisher PO# 57112 Deliver (1) Amerex 859A extinguisher dolly (estimated price + $25 freight) PO# 57113
Troy L.
Kenneth Y.
Monthly Safety Inspection including Portable Fire Extinguishers, Emergency/Exit Lights, Eye Wash Stations, and AEDs. 2018 PO# 57565 Annual Security Fence inspection. Includes visual only inspection for coverage and condition, including gap from ground level. This is for main location at 14187 Nisshinbo Drive only. Annual visual inspection of perimeter lighting of building and street lighting in parking lot and around building. Includes verification of light turning on and is for main location at 14187 Nisshinbo Drive only. Perimeter lighting mounted to the building are connected to timer in SWBD electrical rooms and can be activated. Lights on poles in parking lot and perimeter surrounds can be activated by covering the photocell on top of the light via lift. Boom lift will be delivered on-site for usage. Please be sure to call off lift when completed. Annual hand-held radio coverage inspection. Includes verification of radio coverage between units from one end of the facility t
Kenneth Y.
Portable Extinguishers Inspection Monthly Safety Inspection including Portable Fire Extinguishers, Emergency/Exit Lights, Eye Wash Stations, and AEDs. Check in with David Bland upon arrival. Add in lights at NAMI2. Make sure you have swaps for anything due we still need to swap out. Deficiency: David would like a quote for 25 6v4 & 6v7 batteries
Kenneth Y.
Portable Extinguishers Inspection Annual Fire Extinguisher Inspection
Bobby H.
Portable Extinguishers and Emergency / Exit Lights Inspection
Brett H.
Portable Extinguishers Inspection
Bobby H.
Replaced batteries in exit sign
David S.
Repaired 2nd check valve on backflow