ASA Fire provides fire safety & protection equipment and services to the businesses in Cedartown, GA and the surrounding areas.

Read our reviews and find out why business owners in Cedartown, GA rely on us to keep their property and employees safe.

Local Reviews
for Cedartown, GA

ASA Fire Protection Rated 4.8 out of 5 stars based on 9 customer reviews

Our Reviews by City

Rome, GA (40)


Map of Cedartown, GA 30125

Excellent customer service on scheduling .




Review of ASA Fire Protection

CedartownGA30125 34.045-85.235

Map of Cedartown, GA 30125

Alarm testing




Review of ASA Fire Protection

Great service took care of all our needs.

CedartownGA30125 34.05-85.2375

Map of Cedartown, GA 30125

great service




Review of ASA Fire Protection

CedartownGA30125 34.035-85.24

Map of Cedartown, GA 30125

W




Review of ASA Fire Protection

ww

CedartownGA30125 33.95-85.2775

Map of Cedartown, GA 30125

none




Review of ASA Fire Protection

CedartownGA30125 34.035-85.24

Map of Cedartown, GA 30125

Good service, very nice Tech.




Review of ASA Fire Protection

CedartownGA30125 33.95-85.2775

Map of Cedartown, GA 30125

Great service




Review of ASA Fire Protection

CedartownGA30125 34.0525-85.245

Map of Cedartown, GA 30125

Vice President




Review of ASA Fire Protection

CedartownGA30125 34.015-85.2625

Map of Cedartown, GA 30125

Mets our needs




Review of ASA Fire Protection

CedartownGA30125 33.95-85.2775

Luis M.

Luis M.

Near Melissa Ln, Cedartown, GA 30125
Luis M.

Luis M.

Near West Ave, Cedartown, GA 30125
Luis M.

Luis M.

Near Melissa Ln, Cedartown, GA 30125
Luis M.

Luis M.

Near Melissa Ln, Cedartown, GA 30125
Luis M.

Luis M.

Near Melissa Ln, Cedartown, GA 30125
Jesse C.

Jesse C.

Near N Main St, Cedartown, GA 30125
Jesse C.

Jesse C.

Near Rome Hwy, Cedartown, GA 30125
Luis M.

Luis M.

Near Melissa Ln, Cedartown, GA 30125
Luis M.

Luis M.

Near Cherokee Rd, Cedartown, GA 30125
Troy L.

Troy L.

Alarm Systems and Foam System Suppression Service Call

Near West Ave, Cedartown, GA 30125
Luis M.

Luis M.

Near Sewell Creek Rd, Cedartown, GA 30125
Luis M.

Luis M.

Near Melissa Ln, Cedartown, GA 30125
Bert P.

Bert P.

Near Wissahickon Ave, Cedartown, GA 30125
Bert P.

Bert P.

Backflow Inspection Annual inspection of backflow devices. Inoperable Deficiency: Sprinkler Backflow Pit is filled with water . Will need to be pumped out and tested. Inoperable Deficiency: Back Flow Device Watts 007M1 QT DC SN:181954 failed both Checks at 0.0. Will need to be rebuild and tested.

Near Rome Hwy, Cedartown, GA 30125
Bert P.

Bert P.

Portable Extinguishers Inspection Monthly Inspection of Portable Eye Wash Stations (22) Monthly Pro-Inert and CO2 Cylinder Gauge Check Monthly 3-rotation of Post Indicator Valves (2). Must be recorded in Building Reports Monthly Fire Extinguisher Inspection BRC ID: 372672 (Send report with invoice) Monthly Inspection of Emergency Lights & Exit Lights

Near Sewell Creek Rd, Cedartown, GA 30125
Bert P.

Bert P.

Alarm Systems Inspection Annual fire alarm inspection (all buildings)

Near Cherokee Rd, Cedartown, GA 30125
Bert P.

Bert P.

Portable Extinguishers Inspection Inspect fire extinguishers in vans. Vans are back at facility by 4pm.

Near N Main St, Cedartown, GA 30125
Troy L.

Troy L.

Alarm Systems Service Call Need to replace Vigilant VPS smoke detector in Room 38 that is going bad.

Near Melissa Ln, Cedartown, GA 30125
Bert P.

Bert P.

Portable Extinguishers Inspection Monthly Inspection of Emergency Lights & Exit Lights Monthly Inspection of Portable Eye Wash Stations (22) Monthly Pro-Inert and CO2 Cylinder Gauge Check Monthly 3-rotation of Post Indicator Valves (2). Must be recorded in Building Reports Monthly Fire Extinguisher Inspection BRC ID: 372672 (Send report with invoice) Fire Extinguisher Repairs. - (2) 20lb ABC fire extinguishers are due for 6-year maintenance - (14) 15lbs Halotrons are due for 6-year maintenance - (1) 20lb CO2 Fire Extinguisher is due for hydrostatic testing Inoperable Deficiency: Completed the Annul Inspection for Units 3 and 4. And he the following due for service. 6 15lbs Halotrons are due for Hydro. 1 20lbs CO2 due for Hydro in Unit 3. 1 Plastic Eye wash station on Unit 4 needs to be replaced due to being damaged. **** (15) is the Total of 15 lbs Halotrons for whole plant that are due for Hydro. Only have limited amount of spares at Shop for swaps. Will be swapped 2-4 at a time

Near Sewell Creek Rd, Cedartown, GA 30125
Bert P.

Bert P.

Emergency / Exit Lights, Eye Wash Station, Fire Suppression, Sprinkler, and Portable Extinguishers Inspection Monthly Inspection of Emergency Lights & Exit Lights Monthly Inspection of Portable Eye Wash Stations (22) Monthly Pro-Inert and CO2 Cylinder Gauge Check Monthly 3-rotation of Post Indicator Valves (2). Must be recorded in Building Reports Monthly Fire Extinguisher Inspection BRC ID: 372672 (Send report with invoice) Inoperable Deficiency: Eye wash Holder was damaged will need to be replaced.

Near Sewell Creek Rd, Cedartown, GA 30125
Bert P.

Bert P.

Eye Wash Station, Fire Suppression, Sprinkler, Portable Extinguishers, and Emergency / Exit Lights Inspection Monthly Inspection of Portable Eye Wash Stations (22) Monthly Pro-Inert and CO2 Cylinder Gauge Check Monthly 3-rotation of Post Indicator Valves (2). Must be recorded in Building Reports Monthly Fire Extinguisher Inspection BRC ID: 372672 (Send report with invoice) Monthly Inspection of Emergency Lights & Exit Lights

Near Sewell Creek Rd, Cedartown, GA 30125
Paul T.

Paul T.

Monthly Eye Wash Inspections Monthly portable extinguisher inspection BRC ID: 139838

Near West Ave, Cedartown, GA 30125
Paul T.

Paul T.

Portable Extinguishers Service Call

Near Water Oak Dr, Cedartown, GA 30125
Bert P.

Bert P.

Eye Wash Station, Fire Suppression, Sprinkler, Portable Extinguishers, and Emergency / Exit Lights Inspection Monthly Inspection of Portable Eye Wash Stations (22) Monthly Pro-Inert and CO2 Cylinder Gauge Check Monthly 3-rotation of Post Indicator Valves (2). Must be recorded in Building Reports Monthly Fire Extinguisher Inspection BRC ID: 372672 (Send report with invoice) Monthly Inspection of Emergency Lights & Exit Lights

Near Sewell Creek Rd, Cedartown, GA 30125
Bert P.

Bert P.

Eye Wash Station, Fire Suppression, Sprinkler, Portable Extinguishers, and Emergency / Exit Lights Inspection Monthly Inspection of Portable Eye Wash Stations (22) Monthly Pro-Inert and CO2 Cylinder Gauge Check Monthly 3-rotation of Post Indicator Valves (2). Must be recorded in Building Reports Monthly Fire Extinguisher Inspection BRC ID: 372672 Monthly Inspection of Emergency Lights & Exit Lights

Near Sewell Creek Rd, Cedartown, GA 30125